‘Sav. = Kantrol Engineering Ltd. -2?=~ STRUCTURAL REVIEW / INSPECTION OF a | 2667 Kinqsway Avenue . Port Coquitiam o a SITE INSPECTION. ( Continued ) pe 4 SITE GRADING 1 oe | TE The road facing the buildina ( Kinasway Avenue ? as been raised about a couple of feet since the buildina en was constructed and conseauently the around level at a vo EBS South and East side is above the main floor level. On vgs the North Sice venetation ( qrass) has aqrown riaqht. up to the buildina wali. ow es = FOUNDATION. The foundation wal) and base was exposed at two locations. The bearing surface appears to be adequate , _ i and concrete in the footinas does not exhibit anv Sd bee significant signs of deteriorations. ood The footing wall / bottom sill plate are generaliy below we existing ground level oe No evidence of (differential) settlement was obser ved. 6 SLAB ON GRADE see eMac ne eee deg Slab on grade is aenerally below existing ground level, 7 and is generally covered with carpets or tiles. At pe several locations major cracks were observed. od Minor evidence of water seenade thouch some of the cracks was abserved,. 7 WALLS. The wall finishes were removed at several locations to inspect the studs.sheachino and sill plates. The. bottom sill clates and some studs on South and East sides have detericrated but on North sides they appear to be acteptable at the jocation where they were exposed. The studs, sheathing ¢ interior & exterior ) are qenerally in:cood condition. with minor cracks at few locations. ITEM 1 PAGE 3 |\S | ; ee ree