i i i t i i i i ‘ j ; i : i THE CORPORATION OF THE CITY OF PORT COQUITLAM TON tate EEA aA SALE ead tea ate debe AER ZEAE. Leta neo January 17, 1983. Memo To: Ron Freeman, City Clerk Memo From: Wick Chernoff, Chief Building Inspector Re: 3047 - 3049 York Street Clarification of inspection report of January 11, 1983. 1. Letter from an engineer to be submitted to the building ~ department, that the foundation is adequate (because it appears to be placed on fill with unknowm consolidation) before any more work being done. Rooting application on addition dses not meet Building . Code. requirements, Code requires minimum slope of 4/12 for corrugated roofing with Special fasteners. . The roof - in question has nailing in the valley of the formed metal. with black fibre gum placed over the nail heads, drying of the material could cause a leak in the roof. Solution would ‘be’ to call ina competent roofer to explore possibilities . then submit the proposal to the building department... ... Rectify all framing infractions and call re-inspection prior to covering with drywall. - Sincerely